3 MEGAWATT 5 KV DIESEL PRIMARY POWER GENERATION PLANT WITH 480/600 VOLT SECONDARY
- Street: 44 Oak Road
- City: Blind River
- State/Province: Ontario
- Country: Canada
- Zip/Postal Code: P0R 1B0
- Listed: November 5, 2018 3:27 pm
- Expires: This ad has expired
Description
“COMPLETE – LIKE NEW” 3 MEGAWATT 5 KV DIESEL PRIMARY POWER GENERATION PLANT WITH 480/600 VOLT SECONDARY
– Year: 2008
– Hours: 400
DIESEL ENGINE:
– 3 MW (3000 KW) MTU Detroit Diesel Engine
– Model: 3000SXC60DT2
– Engine Type: 20V-4000-DETROIT
– Configuration: V-20 Cylinders, 4 Stroke
– Aspiration: Twin Turbo Charged, Intercooled
– Dual Fuel Capabilities with Day Tank & Fueling System
– Fuel Currently Used: Diesel #2
– Horsepower: 4680 KW
– RPM: 1800
ALTERNATOR GENERATOR END:
– MTU Synchronous AC Generator Alternator
– Model: AA 28179000
– 3000 KW, 3750 KVA
– Volts: 2402 / 4160
– Amps: 520
– Temp. Rise: 105 Degrees Celsius, AMB.: 40 Degrees Celsius
– Insulation CL: F, Sequence: T1, T2, T3
– Rotation: CWFDE
– Phase: 3,
– Hertz: 60
– Exciter – Field Amps: 6.8, Field Volts: 6.5, PMG Volts: 240, PMG HZ: 240
– 3 Phase, 6 Wire, 60 Hz
– P.F: 0.8, RPM, 1800
– Thompson Technologies ABB Remote Generator Controls
BUILDING NO. 1 GENERATOR HOUSE:
– Includes 3MW Detroit Diesel Generator- Dual Fuel Capability (less than 400 hours, Year: 2008
– Outdoor Cooling Radiators
– Ventialtion Cooling Fans
– Diesel Exhaust System
– HVAC Heating
– Lighting Systems
– Man Doors & Roll-Up Door
BUILDING NO.2 SWITCHGEAR & MCC CONTROL HOUSE:
– PLC Controls
– NGR GFI Over Current Protective Controls
– Front and Back MCC Unit, Including…….
– Eaton Cutler Hammer 5 KV MCC Switchgear Line-Up, 3 Phase, 60 Hz
– 2 x Eaton Cutler Hammer 1200 Amp, 5 KV Motorized 4160 Volts Air Circuit Breakers
– 8 x Eaton Cutler Hamer 4160 Volt, 3 Phase, 60 Hz Fused Disconnect Switches
– Allen Bradley Centerline 2100 MCC 480 to 600 Volt, 3 Phase, 60 Hz MCC Line-Up
– 1 x Allen Bradley Centerline 1600 Amp, 480 to 600 Volt, 3 Phase, 60 Hz Main MCC Disconnect Switch
– 75 x Allen Bradley Centerline 480 to 600 Volt, 3 Phase, 60 Hz MCC Fused Disconnect Switches
– HVAC Heating
– Lighting Systems
– Man Doors & Roll-Up Door
STEP DOWN VOLTAGE TRANSFORMER:
“NEW” HC 3MVA Out Door Pad Mount Step Down Trasnfermer
– 4160 Volt Delta Primery
– 480 Volt Wye Secondary
*Note: 4160 to 600 Volt Transformer Can Also Be Supplied
– 3 Phase, 60 Hz
– Completely Self Contained
*Located Offsite (Pennsylvania, USA)
This “LIKE NEW” 3MW Power Gen-Set/System was used by a major Oil Company for one of their remote site(s) as a Stand-By/Back Up Diesel Power Generation System to provide on-site power mostly during storm conditions.
The MTU Detroit Diesel Generator has Dual Fuel capabilities and is rated for Prime Power @2.75 MW and Stand-By Power @ 3MW). Sparingly used with less than 400 hours of operation, the
System includes Allan Bradley Controls which permits synchronization with the utility grid, allowing seamless switching to gen power in the event of main service/utility power interruption. The package also includes two portable
Buildings housing the Eaton Cutler Hammer 5KV MCC Switchgear Lineup and Allen Bradley Centerline 480/600 Volt MCC Panels, HVAC; Lighting, PLC and all other controls. This is a complete turnkey package that is in “LIKE NEW” Ready to Work Condition.
For pricing and additional details, please contact;
Michael P. Mackwood,
President
The Mackwood Group of Companies Ltd.
44 Oak Rd
Blind River, ON, Canada
P0R 1B0
Tel: 1-705-356-0500
Cell:1-705-849-3249
mike@themackwoodgroup.com
www.themackwoodgroup.com
APPRAISALS – MARKET SURVEYS – SURPLUS EQUIPMENT SALES – MINE LIQUIDATIONS – MARKETING SALES SERVICES
959 total views, 1 today